ABC CABLE, 4X50

ABC CABLE, 4X50

share
  • Detail
  • Parameters

Low voltage power cables

for overhead lines - self-supporting type

NFA2X // SАH - VО

Uo/U  -  0.6/1 kV

Standard: VDE 0276-626/4F //  FN KI 02.003

Al conductors XLPE insulation


Application

The power cables with XLPE insulation for overhead lines - self-supporting type are designed for transfer, distribution and supply with electrical power in networks low voltage Uo/U 0.6/1 kV.

In constructions for distribution networks these cable permit suspension on fasades and trees. They allow crossing of forest areas without cutting and maintenance of openings in the wood.

The suspension and support of the whole bundle is carried out by the phase ( basic ) insulated current- conductive.

Cable construction

Technical data

Construction Conductor

-phase (main)




-additional

for lighting




Insulation


Cable lay up (cable constructions)









Color Marking



М





R

According to VDE 0276-626/4F FN KI 02.003-96

Al stranded compacted or Non-compacted according to VDE 0276-626


Al stranded compacted or Non-compacted according to VDE 0276-626



XLPE with min. 2% carbon black content  type TIX-2 constructions twisted into a bundle include:

phase (main) insulated cores(М)

one, two, or three additional reduced insulated cores for lighting ( R )





black



for NFA2X - to VDE 0276-626 for САХ-ВО - to FN KI 02 003

Operating 80оС

temperature



130оС

Short-circuit temperature




Nominal voltage Uo/U 0.6/1 kV

АС


Highest system

voltage AC, not more 1.2 kV

than




Test voltage

АC -5 min 4 kV

DC - 15 min 10 kV


Bending radius, min. 18xD cable

Temperature of laying no less than - 10оС

recommended 15 оС

Conductor resistance 16 - 1.91 /км 50 - 0.641/км

at 20oC 25 - 1.20 /км 70-0.443 /км

35 - 0.868/км 95 - 0.320/км

16 - 2.84 kN 50 - 8.45 кN

Breaking strengh min. 25 -4.17 kN 70 -11.32 кN

35 - 5.78 kN 95 - 15.68 kN




Construction data

NFA2X / SAH-VO   0.6/1 kV

Number of conductors and nominal cross section


Diameter of bundle approx.

Mass approx.


Allowed current in power supply networks


Allowed current at short- circuit

Mass of Аl cores approx.

Cable weight approx.


N х mm2

mm

kg/km

kg/km

A

kA







1x16rm

9,0

44

74

81

0,8

1x25rm

10,0

67

103

107

1,3

1x35rm

11,0

97

133

132

1,9

1x50rm

12,5

137

185

162

2,7

1x70rm

14,0

187

242

205

3,8

1x95rm

16,0

267

333

245

5,2







2x16rm

18,0

91

152

81

0,8

2x25rm

20,0

139

210

107

1,3

2x35rm

22,0

196

272

132

1,9

2x50rm

25,0

281

277

162

2,7







4x16rm

19,0

181

303

81

0,8

4x25rm

20,0

278

421

107

1,3

4x35rm

25,0

397

543

132

1,9

4x50rm

28,0

562

753

162

2,7

4x70rm

32,0

764

986

205

3,8

4x95rm

44,0

1091

1358

243

5,2







4x25rm+1x16rm

25,0

323

496

107

1,3

4x25rm+2x16rm

28,0

368

572

107

1,3







4x35rm+1x16rm

28,0

442

619

132

1,9

4x35rm+2x16rm

31,0

487

695

132

1,9

4x35rm+1x25rm

29,0

453

645

132

1,9

4x35rm+2x25rm

32,0

536

754

132

1,9







4x50rm+1x16rm

30,0

607

829

162

2,7

4x50rm+2x16rm

34,0

652

905

162

2,7

4x50rm+1x25rm

31,0

631

858

162

2,7

4x50rm+2x25rm

35,0

700

964

162

2,7

4x50rm+1x35rm

32,0

661

889

162

2,7

4x50rm+2x35rm

36,0

760

1025

162

2,7







4x70rm+1x16rm

35,0

810

1061

205

3,8

4x70rm+2x16rm

38,0

855

1137

205

3,8

4x70rm+1x25rm

36,0

834

1091

205

3,8

4x70rm+2x25rm

38,0

903

1196

205

3,8

4x70rm+1x35rm

36,0

854

1121

205

3,8

4x70rm+2x35rm

40,0

963

1257

205

3,8







4x95rm+1x16rm 4x95rm+2x16rm

41,0

44,0

1136

1181

1434

1510

245

245

5,2

5,2

4x95rm+1x25rm

42,0

1160

1463

245

5,2

4x95rm+2x25rm

45,0

1230

1569

245

5,2

4x95rm+1x35rm

42,0

1190

1494

245

5,2

4x95rm+2x35rm

46,0

1289

1630

245

5,2



Part No.
UNABC
Type
ABC CABLE
Voltage
0.6/1 kv
Size
25-150mm2
Conductor
Aluminum
Insulation
XLPE